BRAYDEN Baby | CPR | Light skin M17020
Infant CPR differs significantly from pediatric and adult CPR. Due to a smaller mouth and airway, a relatively larger tongue and occiput, delicate lungs, and a rib structure that is more flexible yet less rigid than that of adults, infant CPR requires a more precise technique. The BRAYDEN (IM17020) is designed to accurately reflect these unique characteristics.
One of the most critical aspects of infant CPR is the proper ventilation technique that avoids overventilation. Overventilation is a leading cause of failure in infant resuscitation and can result in irreversible lung damage. The BRAYDEN (IM17020) features a dedicated lung indicator that guides users in delivering the correct ventilation volume, helping them develop proper technique and confidence in training.
Lighting the Way to High-Quality CPR
(Lighting the way to Quality CPR)
Designed with input from experts, its integrated lights provide intuitive real-time feedback, guiding learners to perform accurate ventilation and high-quality chest compressions.
These capabilities are essential for optimizing survival outcomes in real-life situations. In my view, the BRAYDEN Baby is a truly unique manikin with these capabilities.”— Prof. Patrick Van de Voorde, Pediatrician and Clinical Lead in Emergency Medicine, Ghent University Hospital, Belgium
Ventilation
Proper ventilation in infants requires correct airway positioning (neutral position) and appropriate ventilation volume.
The BRAYDEN (IM17020) provides real-time feedback to help learners perform high-quality ventilation.
- Ventilation Volume
- For an infant of a size comparable to the BRAYDEN (IM17020), the appropriate ventilation volume is 30–50 mL.
The manikin’s ventilation indicator provides visual feedback on the actual volume of air delivered and whether it is delivered with excessive force.
-

Proper Ventilation
When the lung-shaped ventilation indicator illuminates, learners can confirm that the correct ventilation volume has been delivered.
-

Overventilation
Provides an alert when excessive ventilation volume is delivered.
-

Rapid Ventilation
A double-flash indicator alerts users when ventilation is delivered too quickly, in less than one second.
Proper Head and Airway Position
The BRAYDEN (IM17020) infant manikin is designed to allow learners to practice jaw thrust and chin lift techniques.
For effective ventilation in infants, it is essential to maintain the head in a neutral position to keep the airway open.
Excessive head tilt (overextension) or flexion (chin-down position) is inappropriate during infant ventilation.
The BRAYDEN (IM17020) features a relatively large occiput, causing the head to rest naturally in a flexed position, similar to that of a real infant. As a result, learners must adjust the head to the correct neutral position to open the airway.
-

Jaw Thrust
The jaw mechanism is designed to replicate the natural movement of an infant’s jaw, enabling accurate jaw thrust techniques.
-

Head Tilt and Chin Lift
The airway opens only when the head is correctly positioned in the neutral position.
-

Proper Airway Opening Position
Due to the proportionally larger occiput, the manikin naturally rests with the head in a flexed position, similar to a real infant.
Learners must adjust the head to the correct neutral position to open the airway. -

Excessive Head Tilt
Excessive head tilt can obstruct the airway, replicating real-life conditions.
High-Quality Chest Compressions
With real-time blood flow feedback from the BRAYDEN (IM17020) infant manikin, learners can perform high-quality chest compressions.
Guideline Parameters: The recommended compression depth is at least one-third of the chest depth (approximately 4 cm), with a compression rate of 100–120 per minute.
CPR Quality Indicator

The forehead indicator on the manikin illuminates when all of the following criteria are met:
- Correct Compression Depth
- Correct Compression Rate
- Full Chest Recoil
- Correct Hand Placement
-

Compression Depth Indicator
– Excessive CompressionThe correct compression depth for infants is one-third of the chest depth (approximately 4 cm).
-

Compression Depth Indicator
– Shallow CompressionThe correct compression depth for infants is at least one-third of the chest depth (approximately 4 cm).
-

Compression Rate Indicator
– Fast / Slow CompressionsThe appropriate compression rate is 100–120 compressions per minute.
Above 120 compressions per minute: The side forehead indicator flashes rapidly.
Below 100 compressions per minute: The side forehead indicator flashes slowly. -

CPR Quality Indicator
– Incomplete Recoil or Incorrect Hand PlacementThe chest and side forehead indicators may illuminate, but the forehead indicator will not turn on.
Adjust finger/thumb placement or ensure full chest recoil between compressions.
Specifications
| General Information | |
| Type | Full-body |
| Visualized blood flow from the heart to the brain | check |
| Chest compression depth and rate sensors | check |
| Realistic chest rise during ventilation | check |
| Head tilt & chin lift (airway opening) | check |
| Jaw Thrust | check |
| Airway | Disposable |
| Ribs, Xiphoid | check |
| Audible click feedback for the chest compression | check |
| Realistic tongue structure | check |
| Dimensions and Weight | |
| Dimensions (L × W × D) | 224 x 550 x 115 mm(8.8 × 21.7 × 4.5 in) |
| Weight | 1.72 kg (3.8 lb) without batteries |
| Weight (Packaged) | 4.0 kg (8.8 lb) gross / 3.0 kg (6.6 lb) net |
| Dimensions (Packaged) | 330 x 200 x 630 mm(13.0 × 7.9 × 24.8 in) |
| Operating Conditions | |
| Operating Temperature | 0°C ~ 40°C (32°F ~ 104°F) |
| Storage Temperature | -20°C ~ 60°C (-4°F ~ 140°F) |
| Humidity | 5% - 95% RH |
| Power and Other Specifications | |
| Warranty | 2 years (excluding consumables) |
| Power | Input: AC 100–260 V / Output:DC 9 V, 1 A Battery: 6 × AA 1.5 V batteries |

-
Face Skin

-
Body Skin

-
Face Shield

-
Artificial Lung

-
Dual-Layer Ventilation Filter

-
Infant Diaper

-
Bodysuit

-
Blanket

-
AC Adapter